• iocase@lemmy.zip
    Aquileo | link
    Aquileo | fedilink
    Aquileo | arrow-up
    4
    ·
    2 days ago

    I wonder how this works. Maybe it only functions when it detects the wall has 120V power? If it backfed during a power outage it would be like plugging a generator into your house with a cheater cord (never, ever do that) which can step your generators 120V back up into 12-25kV through your local transformer and zap the linesman working to fix your outage on the neutral (a generator backfeeds onto the neutral not the “hot” sides of the circuit. I.e. the “safe” wire suddenly has thousands of volts on it)

    • cynar@lemmy.world
      Aquileo | link
      Aquileo | fedilink
      English
      Aquileo | arrow-up
      4
      ·
      2 days ago

      The European systems definitely have line sensing. They need to, to stay in phase. If the power goes, so does your solar.

      I think some systems can be turned on from an app, but default to off, without mains as a reference.

      • cheesemoo@lemmy.world
        Aquileo | link
        Aquileo | fedilink
        Aquileo | arrow-up
        2
        ·
        2 days ago

        Huh, I wonder how that works. How can it differentiate grid power vs the power it’s supplying to the wall? All I can guess is maybe it polls for grid power by cutting its own supply for a few milliseconds to see if the grid is still there? Couldn’t find anything getting into the details online…

        • cynar@lemmy.world
          Aquileo | link
          Aquileo | fedilink
          English
          Aquileo | arrow-up
          2
          ·
          2 days ago

          I believe they try and shift the phase slightly. If the mains in present, it will overwhelm the inverter and keep it locked, or at least show up as a distorted waveform. If it can swing the phase freely, then there is no mains power, so it shuts down.

          E.g. (in Europe) an oscillator with a frequency of 49.95 will be dragged to the mains 50.00. By measuring the frequency it will read 50.00, if it drifts low, then it is not phased locked, and so will shut itself down till 50hz reappears.

          Think of it like how metronomes come into harmony. Only 1 is a little desktop unit (your inverter) and the other is building sized (the grid).

          • cheesemoo@lemmy.world
            Aquileo | link
            Aquileo | fedilink
            Aquileo | arrow-up
            2
            ·
            1 day ago

            Ohh shit, yeah I bet that’s it! Smart. I was thinking with a DC mindset, but it would be able to notice when the grid is pushing back or not if it’s even a little out of sync.

  • cmbabul@slrpnk.net
    Aquileo | link
    Aquileo | fedilink
    Aquileo | arrow-up
    7
    ·
    3 days ago

    I hope more apartment complexes and buildings will allow this, I’ve got a bunch of sun that hits my balcony all day when it’s sunny. Would love to cut my power bill and move more into sustainability